Model: Smart FNC
Technology: RF Microneedling Machine
| Screen | 13.3-Inch Fully Laminated Screen |
| Frequency | 1MHz / 4MHz / 8MHz |
| Input Voltage | 110V/220V |
| Input Frequency | 50Hz / 60Hz |
| Vacuum Negative Pressure | Max. 70KPa |
| Pressure | 30KPA, adjustable according to customer needs |
| Microneedle Diameter | Max 0.2 mm |
.jpg)
01 Smart panel: Android 2.0 system clearly displays the directions and ways for guiding the handpiece. The screen shows exactly how the treatment should be performed like an assistant and trainer guide near you. And automatically recognizes needle size, matches treatment area, and recommends clinical parameters.
02 Insulated & non-insulated needle Dual-Mode:
Non-insulated Microneedles (Traditional): Energy is released along the entire needle, providing extensive thermal stimulation ideal for treating skin laxity and deep wrinkles with high efficiency. The drawbacks include a higher risk of epidermal injury and significant discomfort.
Insulated Microneedles (Advanced): Energy is concentrated solely at the needle tip, ensuring precise, layered treatment with superior epidermal safety, minimal pain, and a very low risk of hyperpigmentation. However, the treated volume per session is smaller, potentially requiring more sessions for full-face results.
03 Safety: 415nm blue light for antibacterial and anti-inflammatory effects.
04 Impedance-based safty system:
05 Sterile: Every needle is independently packaged after EO sterilization method, ensuring safety, hygiene, and freedom from contamination

01 Painless 0.1mm
Featuring an industry-leading 0.1mm ultra-fine needle diameter, the system significantly reduces treatment pain, bleeding, and thermal damage. This results in a shorter recovery period, easier aftercare, and lower risk of infection and hyperpigmentation, allowing patients to renew their skin with minimal downtime.
02 Accurate
Smart FNC with Negative pressure adsorption technology, effectively solve the problem of poor consistency in penetration depth of traditional microneedles, improving clinical results by more than 20%. Vacuum makes the skin smooth and firm during microneedle treatment, and the needle insertion depth is uniform. Finally, it triggers the production of capillaries, elastin, and collagen, producing an overall tightening and lifting effect.
03 Fractional
Fractional technology minimizes damage to surrounding healthy skin by controlling energy release, allowing for precise targeting of different skin depths and areas. The SmartFNC system is equipped with 10-pin, 36-pin, 60-pin, and non-invasive RF tips, enabling adjust needle length and RF energy intensity. Reduces patient discomfort and recovery time.
04 Radio frequency
1MHz, 4MHz, 8MHz, 3 types of RF energy can be selected for different areas, resulting in improved treatment efficacy.
01 RF Handle (body)
For big area fat removal and fine lines, pores, radiance, hydration, mild tightening
02 Microneedling Handle
RF+Microneedling+Vacuum+Fractional+415nm blue light
The microneedling handle can be adapted to 4 kinds of needles to meet the treatment needs of different parts of the body.
03 Cooling & Heating Handle
Clinical use of heating hammer: heating the epidermis before the operating superficial fractional RF treatment, loosen the pores and make the microneedles and products penetrate better to exert their effects. Moreover, making it more effective for lifting and tightening the skin, to promote metabolism.
When cryotherapy is administered prior to treatment, it induces a state of localized skin numbness, thereby significantly reducing the sensation of tingling or discomfort.
Conversely, when applied following the procedure, it helps to rapidly constrict pores, alleviate epidermal discomfort, and effectively soothe the skin, thereby minimising redness, swelling, and erythema.
04 Skin Analyzer
Skin and scalp detection
(UV light, Turbine light, White light)
*Health scalp
*Oily scalp
*Dry scalp
*Sensitive scalp
*Health skin
*Information
*Dehydrated skin
*Anti redness

Clinical use of heating hammer: before the treatment, it can heat the epidermis loosen the pores and make the microneedles and products penetrate better to exert their effects;
Clinical use of cooling hammer: after the treatment, quickly shrink pores, relieve epidermal pain, and reduce skin redness, swelling, and erythema;
√ Cooling mode: cooling temperature 0℃~5℃
√ Heating mode: heating temperature 35℃~50℃

Applications of RF Microneedling Machine Smart FNC
Collagens remodeling
Encourage collagens
Improve elasticity
Dermis penetration
Skin lifting and tighten
Enlarged pores
Fine lines or wrinkles
Sagging skin
Acne scars
Skin discoloration
Stretch marks
Regular skin care and all-round maintenance






Every needle comes in its own individually packaged and labeled pouch, sterilized with EO technology for guaranteed safety and hygiene.



Screen | 13.3-Inch Fully Laminated Screen | |||
Frequency | 1MHz / 4MHz / 8MHz | |||
Power | 100W (8MHZ for the corners of the eyes, 4MHZ for the cheeks and neck, and 1MHZ for the body) | |||
Input Voltage | 110V/220V | |||
Input Frequency | 50Hz / 60Hz | |||
Vacuum Negative Pressure | Max. 70KPa | |||
Pressure | 30KPA, adjustable according to customer needs | |||
Microneedle Diameter | Max 0.2 mm | |||
Needle Removal Interval | 0.5 ~ 4.0 mm (varies in different parts) | |||
Needle Identification | Support | |||
Needle Chart Combination | 10 * 1 | 6 * 6 | 8 * 8 | Nanocrystal head |
10-needle | 36-needle | 64-needle | / | |
Independent Sterilization Label | Individual packaging and individual labeling for more assured sterilization status (ethylene oxide sterilization) | |||
Product Size | Micro-needle machine | Refrigeration machine | Complete machine | |
434*326*255 mm | 406*392*173 mm | 438*391*386 mm | ||
Package Size | 530*620*410 mm | / | 530*620*510 mm | |
Product Weight | 10KG | 10KG | 20KG | |